Skip to content
Currency

Flat 5% OFF on Premium Tuning Forks

Pre-sterilized Nylon-66 Membrane Syringe Filters

Pre-sterilized Nylon-66 Membrane Syringe Filters

Regular price $299.00 USD
Tax included.
The Pre-Sterilized Nylon-66 Membrane Syringe Filters from Scilabex are designed for precise...
Quantity:
Estimated Delivery:
people viewing this product right now!
Tags:0.2 micron syringe filter, hplc syringe filters, laboratory filtration filters, membrane syringe filters, microbiology syringe filters, nylon 66 syringe filters sterile, pharmaceutical syringe filters, pre sterilized nylon syringe filters, sterile filtration filters
Guaranteed Safe Checkout
Get It Today

Free shipping

Free shipping on orders over $75.

100 - Day Returns

Not impressed? Get a refund. You have 100 days to break our hearts.

Dedicated Support

Support from 8:30 AM to 10:00 PM everyday

DescriptionSpecifications

    The Pre-Sterilized Nylon-66 Membrane Syringe Filters from Scilabex are designed for precise and contamination-free filtration in critical laboratory and pharmaceutical applications. These advanced laboratory syringe filters offer excellent chemical compatibility, low extractables, and validated bacterial retention for reliable sterile filtration.

    Widely used across the USA and global laboratories, these filters are ideal for applications requiring high purity, minimal sample loss, and consistent performance.

    What are Pre-Sterilized Nylon-66 Syringe Filters?

    These syringe filters are gamma sterilized and ready-to-use filtration devices featuring a hydrophilic Nylon-66 membrane. They provide efficient removal of bacteria and fine particles while ensuring minimal interference with the sample.

    They are commonly used for:

    • Sterile filtration of biological and pharmaceutical samples
    • Chemical and solvent filtration
    • Critical lab and research applications

    Applications

    The Pre-Sterilized Nylon-66 Membrane Syringe Filters are widely used in:

    • Sterile filtration of DMSO for cryo-preservation of stem cells
    • Particulate removal from pharmaceutical parenterals before administration
    • General sterile filtration in laboratory environments

    These filters are ideal for both biological and chemical applications.

    Special Features

    • Absolute retention for reliable sterilization
    • Low hold-up volume for minimal sample loss
    • Minimum back pressure for smooth filtration
    • Extremely low extractables for accurate results
    • Hydrophilic membrane – no pre-wetting required
    • Wide chemical compatibility
    • Heat sealed to ensure ‘no leaching’
    • No initial flushing required
    • Validated for bacterial retention as per ASTM F838

    Specifications

    Construction

    • Membrane: Nylon-66 Membrane
    • Pore Size: 0.2µm, 0.45µm
    • Diameter:
      • 4mm
      • 13mm
      • 25mm
    • Inlet: Female luer-lock
    • Outlet: Male luer slip
    • Housing: Polypropylene

    Operational

    • Max. Operating Temperature: 55 °C
    • Max. Differential Pressure: 75 psi @ 25°C
    • Burst Pressure: >12 kg/cm²

    Hold-up Volume (with air purge):

    • <5µl (4mm)
    • <20µl (13mm)
    • <50µl (25mm)

    Effective Filtration Area:

    • 0.07 cm² (4mm)
    • 0.8 cm² (13mm)
    • 4.15 cm² (25mm)

    Bubble Point:

    • (0.2µm): >50 psi (>3.52 kg/cm²)
    • (0.45µm): >32 psi (>2.25 kg/cm²)

    Clean Water Flow Rate @ 20 psi (0.2µm):

    • 0.5 ml/min (4mm)

    • 6 ml/min (13mm)

    • 40 ml/min (25mm)

    Clean Water Flow Rate @ 20 psi (0.45µm):

    • 1 ml/min (4mm)

    • 10 ml/min (13mm)

    • 80 ml/min (25mm)

    Sample Volume:

    • <1 ml (4mm)
    • <10 ml (13mm)
    • <100 ml (25mm)

    Retention Efficiency:

    • (0.45µm): LRV >7 for S. marcescens (ATCC 14756)
    • (0.2µm): LRV >7 for Brevundimonas diminuta (ATCC 19146)

    Key Benefits

    Sterile & Ready to Use

    • Gamma sterilized for immediate use
    • Eliminates contamination risks

    High Filtration Efficiency

    • Absolute retention of bacteria and particles
    • Ensures high purity samples

    Low Sample Loss

    • Low hold-up volume preserves valuable samples
    • Ideal for small volume applications

    Wide Compatibility

    • Suitable for aqueous solutions and many solvents
    • Versatile for multiple lab applications

    How to Use

    1. Open the sterile packaging carefully
    2. Attach the filter to a syringe
    3. Draw the sample into the syringe
    4. Filter into a sterile container

    Ordering Information

    Type

    Type Code
    Presterilized Nylon-66 Membrane Syringe Filter SYNN

    Size

    Diameter Code
    4mm 01
    13mm 03
    25mm 06

    Pore Size

    Pore Size Code
    0.2µm 01
    0.45µm 02

    Inlet / Outlet

    Description Code
    Female luer-lock M
    Male luer slip N
    XX

    Sterility

    Type Code
    Gamma Sterile 3

    Pack Size

    Pack Size Code
    100 04

    Shopping cart

    Your cart is currently empty.

    Continue shopping
    Chat with us

    👋 Hi, message us with any questions. We're happy to help!

    Instant answers

    What are your shipping details?
    Track my order
    Do you ship internationally?

    Before we get started

    Please provide your information so we can reply to you if you leave the chat.

    By proceeding, you agree to share your details for customer support.